The automatic water level monitoring system – Model EWLR-101 – is used to get administers significant quantitative data on the magnitude of the water column, water table and the temperature in a borehole. The system contains an absolute water level sensor with a cable and an automatic data logger with the required data retrieval/transmission options.
The data logger is programmed to automatically store the water head/pressure data at fixed intervals with a minimum scan/upload interval from 5 seconds to 168 hours with different options to download the data. Data transmission can be set remotely at scheduled times with telemetry (GSM/GPRS inbuilt modem) or downloaded on a laptop/mobile in the field through Bluetooth or a cable. The water level data can be modified for specific gravity variations in water.
Automatic Water Level Monitoring System EWLR-101
Input EPP-30V, EPP-40V, EPP-60V pressure sensor Sensor Range (MPa) EPP-30V: 0.2, 0.35, 0.5, 0.7, 1.0, 1.5, 2.0, 3.5 (20, 35, 50, 70, 100, 150, 200, 350 m WC)
EPP-40V: 0.35, 0.5, 0.7, 1.0, 2.0 (35, 50, 70, 100, 200 m WC)
EPP-60V: 0.10, 0.20 (10, 20 m WC)Sensor Accuracy ± 0.2 % fs standard | ± 0.1 % fs optional Cable CS-1102 or CS-1302 four conductor Data logger ESCL-10VT/ESDL-30 Logger Memory capacity 8 MB Flash RAM, can store 3,145,728 data points Communication port One RS-232 serial port Measuring modes Linear or event sampling Power supply Lithium cells, Battery life is more than 5 years for 4 measurement/day and one transmission/day. Bluetooth port Detachable dongle