The condition monitoring sound level meter is an optimal sound level meter for measurements at workplaces, construction sites, in traffic, airports, etc. The sound level meter is a class 2 device and is equipped with an octave band frequency filter. The sound level meter can optionally be upgraded with a 1/3 octave band filter. In addition to the numerical display of the measured value, a graph can show the course of the sound level. The sound level meter has various frequency weightings such as A, B, C and Z. The sound meter can also display measurements with the time weightings Fast, Slow, Impulse and Peak. The measuring range of the sound level meter extends from 25 ... 136 dbA at a frequency of 20 Hz ... 12.5 kHz. 3 different measurement profiles can be stored in the sound level meter. Here the user can decide which parameters the sound level meter should record. For example, you can choose between Laeq, LcPeak, LaFmax, LaFMin, etc.

The peak hold function in the condition monitoring sound level meter makes it possible to record the maximum sound pressure level during long-term measurements and freeze it in the display. A 24 bit AD converter and the specially developed electronics of the sound level meter help to reduce the inherent noise to a very low level. Sampling the measurement signal with more than 48 kHz enables high accuracy and improved stability of the measurement value on the sound level meter.

 

Manual

Condition Monitoring Sound Level Meter PCE-428-Kit-N with Sound Calibrator

  • 1/1 octave band included

    - 1/3 octave band optional

    - Accuracy class 2 

    - A, B, C & Z Frequency weighting

    - Fast, Slow, Pulse and Peak time weighting

    - Statistics function

    - Display of the sound curve as a graph

    - 3 measurement profiles adjustable

    - Low inherent noise

    - ICCP microphone 40 mV /PA

    - Alarm level adjustable

  • Measuring range

    25 ... 136 db(A)

    Accuracy

    Class 2

    Frequency range

    20 Hz ... 12.5 kHz

    Standards

    GB/T 3785.1-2010
    GB/T 3785.2-2010
    IEC 60651:1979
    IEC 60804:2000
    IEC 61672-1:2013
    ANSI S1.4-1983
    ANSI S1.43-1997

    Frequency analysis

    1/1 Octave band filter: 20 Hz ... 8 kHz
    1/3 Octave band filter: 20 Hz ... 12.5 kHz

    Microphone

    1/2" microphone Class 2
    Sensitivity: 40 mV/PA
    Frequency range: 20 Hz ... 12.5 kHz
    Connection: TNC
    Power supply: ICCP Standard

    Data-logging interval

    1 s ... 24 h (adjustable)

    Measuring functions

    LXY (SPL), LXeq, LXYSD, LXSEL, LXE, LXYmax, LXYmin, LXPeak, LXN

    X = Frequency weighting: A, B, C, Z
    Y = Time weighting: F, S, I
    N = Statistics in %: 1 ... 99%

    Frequency weightings    

    A, B, C, Z

    Time weightings

    Fast (F) 125ms, Slow (S) 1 sec, Impulse (I) 35 ms

    Inherent noise

    Microphone: 20 db(A), 26 db(C), 31 db(Z)
    Electronics: 14 db(A), 19 db(C), 24 db(Z)

    AD converter

    24 Bit

    AD Sample rate

    Standard: 48 kHz
    LN Mode: 20 ms

    Measuring display

    Numerical
    Bar graph
    Graphical

    Display

    160 x 160 pixel LCD with backlight

    Memory

    4 GB Micro SD card

    Interface

    USB (Memory readable via software or directly as mass storage)
    RS-232

    Voltage output

    AC 5V RMS
    DC 10 mV/db

    Alarm

    Adjustable

    Power supply

    4 x 1.5V AA Batteries
    12V / 1 A Power plug
    5V / 1 A USB

    Battery life

    Min. 10 h continuous use

    Dimensions

    70 x 300 x 36 mm / 2.76 x 11.81 x 1.42 in (W x H x D)

    Weight

    Approx. 620 g / 1.4 lbs incl. batteries

       
    Class 2 Sound Calibrator PCE-SC 43
    Sound pressure level 94 dB, 104 dB, 114 dB
    Accuracy ±0.4 dB
    Class 2
    Frequency 1000 Hz for A, B, C and D frequency weighting
    Frequency accuracy ±1.7 % 
    Stabilization time 10 seconds
    Total harmonic distortion   <3 %
    Environmental conditions  
    Temperature influences <0.4 dB at 0 ... 40 °C / 32 ... 104 °F
    Humidity influences 25 ... 90 % RH
    Atmospheric pressure <0.1 dB at 65 ... 108 kPa
    Stability at <60 seconds ±0.15 dB
    Stability after one year ±0.35 dB
    (normal use)  
    Operating conditions 0 ... 40 °C / 32 ... 104 °F, <25 ... 90 % RH,
      non-condensing
    Storage conditions -20 ... 50 °C / -4 ... 122 °F, <90 % RH,
      non-condensing
    Automatic shutdown after 20 minutes
    Power supply 2 x 1.5 V AA batteries
    Battery life ca. 50 hours
    Microphone size 1/2 inch
    Dimensions 60 x 130 x 37.5 mm / 2.3 x 5.1 x 1.4"
    Weight 400 g / 14.1 oz