top of page

The manometer PCE-DMM 51 is suitable for flush mounting hygiene applications. Thus, the manometer can be installed both in the food industry as well as in the medical industry. The manometer shows on its rotatable display pressures up to 400 bar, absolute or relative. The operating fluid of the manometer has a food safe FDA approval. The flush mounting of the manometer can be sterilized. The indicator on the manometer is rotatable.

copy of Manometer DMM 51

  • Nominal pressure relative in Bar 60 100 160 250 400
    Overload in Bar 100 200 400 400 600
    Burst pressure in bar 120 250 500 500 650
    General Specifications
    Accuracy < ± 0.25 % FSO
    Measuring rate 5/s
    Long term stability < ±0.1 % FSO
    Media

    Water
    Paints and varnishes
    Gases
    Viscous and paste media

    Temperature ranges Fluid: -20 ... 85 °C
    Operating: -20 ... 70 °C
    Storage: -30 ... 80 °C
    Pressure port / housing Stainless steel 1.4404
    Seal FKM
    Diaphragm Stainless steel 4.4435
    Parts exposed to liquid Pressure port, seals, diaphragm
    Display LC Display
    Power supply 2 x 3.6 V Lithium Battery (1/2 AA)
    Battery life 1.5 year standby
    Protection IP65
    Weight ca. 350 g