The Xgard Type 1 gas leak detector is a robust, intrinsically safe gas sensor for toxic gases and oxygen. The Xgard Type 1 gas leak detector is available in 10 different versions, depending on the gases for which it is to be used. The gas measuring device measures the respective gases with the help of an electrochemical detector. The Xgard Type 1 can easily be connected to existing measuring and warning devices via the 2-wire 4 ... 20 mA output. The gas leak detector also impresses with its easy installation and maintenance, as well as its robust construction made of glass fiber reinforced nylon, which is IP65 protected.
Gas Leak Detector Xgard Type 1 SO2
- 10 different versions available
- Intrinsically safe construction with ATEX approval
- Electrochemical detector
- 2-wire 4 ... 20 mA output
- Easy installation and maintenance
- Robust housing made of glass fiber reinforced nylon
- IP 65
Technical specifications Sensor type electrochemical Housing ATEX certified:
glass fiber reinforced nylonCan be used in EX zones 0, 1, 2 Detectable gases (depending on the version) 0...25 vol% O2 (oxygen)
0...2000 ppm H2 (hydrogen)
0...250 ppm CO (carbon monoxide)
0...50 ppm NH3 (ammonia)
0...5 ppm Cl (chlorine)
0...1 ppm O3 (ozone)
0...10 ppm SO2 (sulfur dioxide)
0...1 ppm PH3 (phosphane)
0...25 ppm H2S (hydrogen sulfide)
0...10 ppm NO2 (nitrogen dioxide)
0...25 vol% O2 (oxygen)Response time T90 T90 Protection class IP 65 Signal output 2-wire 4 ... 20 mA output Cable inputs M20 Approval ATEX: EX II 1 G
Exia IIC T4 (Tamb -40 ... +55 °C / -40 ... 131 °F)
UL/cUL: Cl I, Div 1
Groups A, B, C, D
IECEx
MED Marine (oxygen only)
GOST-REMC compliance EN 50270
FCC part 15
ICES-003Operating voltage 8...30 V DC Power consumption 24 mA max. Temperature range -20 ... +50 °C / -4 ... 122 °F Humidity 15 ... 90 % RH Dimensions 156 x 166 x 111 mm / 6.14 x 6.53 x 4.37" Weight 0.5 kg / 1.1 lb