PHD 1 Multifunction Conductivity Meter is a portable, easy-to-use measuring device with multiple capabilities for inspecting water quality. Offering extraordinary precision at an affordable price, the Multifunction Conductivity Meter is used for laboratory and in situ testing of the pH value, redox, conductivity, salt content, oxygen level and temperature of water. Three-point calibration and automatic temperature compensation guarantee a high level of accuracy even with variable temperature measurements. PHD 1 comes with both a pH electrode and a conductivity electrode. Additional electrodes are available for purchase separately, as is an optional mains adapter for power and a software kit with an RS-232 cable. PHD 1 acts as a real-time data logger. All values can be stored directly on the included SD card in Microsoft Excel format or transferred to a PC by means of the RS-232 port. Thus, no additional software is required for evaluation of the data.
Multifunction Conductivity Meter PHD 1
pH measurement
Measurement range: 0 ... 14.0 pH
Resolution: 0.01 pH
Accuracy: ±0.02 pH + 2 digits
Calibration: 3 points (pH 4, pH 7, and pH 10)
Temperature compensation: Automatic with additional temperature sensor (0 ... 60 ºC / 32 ºF ... 140 ºF) or manual (0 ... 100 ºC / 32 ºF ... 212 ºF)
Conductivity
Measurement range: 0 ... 200 µS/cm, 0.2 ... 2.0 mS/cm, 2 ... 20.0 mS/cm, 20 ... 200 mS/cm
Resolution: 0.01 µS/cm, 0.001 mS/cm, 0.01 mS/cm, 0.1 mS/cm
Accuracy: ±2 % of the measurement range + 1 digit
Calibration: 1413 mS/cm
Temperature compensation: Automatic (0 ... 60 ºC / 32 ºF ... 140 ºF)
Total dissolved solids (TDS)
Measurement range: 0 ... 132 ppm, 132 ... 1320 ppm, 1320 ... 13200 ppm, 13200 ... 132000 ppm
Resolution: 0.1 ppm, 1 ppm, 10 ppm, 100 ppm
Accuracy: ±2 % of the measurement range + 1 digit
Temperature compensation: Automatic (0 ... 60 ºC / 32 ºF ... 140 ºF)Salt content
Measurement range: 0 ... 12 % (of weight)
Resolution: 0.1 %
Accuracy: ±0.5 % of the measurement range
Temperature compensation: Automatic (0 ... 60 ºC / 32 ºF ... 140 ºF)
Oxygen
Measurement range: 0 ... 20 mg/l (in water), 0 ... 100 % (in air), 0 ... 50 ºC / 32 ºF ... 122 ºF
Resolution: 0.1 mg/l, 0.1 %, 0.1 ºC
Accuracy: ±0.4 mg/l, ±0.7 %, ±0.8 ºC
Calibration: In the air
Temperature compensation: Automatic (0 ... 50 ºC / 32 ºF ... 122 ºF)
Temperature
Measurement range: 0 ... 60 ºC / 32 ºF ... 140 ºF
Resolution: 0.1 ºC
Accuracy: ±0.8 ºC
Temperature compensation: Automatic (0 ... 60 ºC / 32 ºF ... 140 ºF)
General specifications
Measurement rate: 1 second up to 9 hours
Display: LCD
Memory: SD card up to 16 GB (2 GB card included)
Interface: RS-232
Software: Optional
Power supply: 6 x 1.5 V AA batteries (optional power adapter)
Operating conditions: 0 ... +50 ºC / < 85 % RH
Dimensions: 177 mm x 68 mm x 45 mm / 7.0 in x 2.7 in x 1.8 in