top of page

he Roughness Tester RT 1200 is used to determine surface roughness. The compact roughness tester is a handheld device for mobile use. Due to the power supply via a powerful battery, it can be used directly on site. The roughness tester is used in the laboratory, in production and everywhere where the roughness of surfaces is to be determined. The measured values are displayed on the clear and user-friendly OLED display directly on the measuring device. In addition, the roughness tester has a storage option for up to 20 measured values, which can later be read out via the micro USB interface. For this purpose, the measurement software can be used, and a USB cable is included in the delivery. The built-in rechargeable battery is also charged via the micro USB interface. The above mentioned measurement software is particularly suitable when measurement series are pending. The data is then transferred to the software and can be evaluated directly on the screen.

The roughness meter has a protective cap for the sensor, which protects it from external influences and can be easily screwed to the device. A calibration plate with roughness standard is also part of the standard equipment and serves to check the correctness of the measurement results.
 

Rz = average roughness 
The average roughness Rz is the arithmetic mean of the largest single roughness depths of several adjacent individual measuring sections.
Ra = arithmetic centers roughness
Ra is the generally recognized and internationally applied roughness parameter. It is the arithmetic mean of the absolute values of the profile deviations within the reference line. The measured value Ra is always smaller than the Rz value determined on the same roughness profile.

Roughness Tester RT 1200

  • Measurement parameters Ra, Rz, Rq, Rt
    Measuring ranges Ra, Rq: 0.005 ... 16.00 µm / 0.197 ... 629.921 µin
    Rz, Rt: 0.002 ... 200.0 µm / 0.079 ... 7874.016 µin
    Radius probe tip 5 µm/ 196.850 µin
    Material probe tip Diamond, 90° angled
    Max. recommended force for static measurement     4 mN (0.4 gf)
    Radius longitudinal guide bar 45 mm / 1.77"
    Maximum driving distance 15 mm / 0.59"
    Measuring principle Inductive
    Cut-off wavelength 0.25 mm / 0.8 mm / 2.5 mm 

    0.009" / 0.03" / 0.098"

    Testing speed 0.135 mm/s at cut-off wavelength: 0.25 mm
    0.5 mm/s at cut-off wavelength: 0.8 mm
    1 mm/s at cut-off wavelength: 2.5 mm
    Reversing speed: 1 mm/s
    Measuring accuracy < ± 10%
    Repeatability < 6%
    Display OLED
    Units μm / μinch (switchable)
    Interface Micro-USB
    Power supply Rechargeable Li-ion battery
    Dimensions L x W x H 150 x 60 x 43 mm / 5.9 x 2.36 x 1.69 in
    Weight 370 g / < 1 lb